One Bloor
Toronto, ON
76 Storeys
General Contractor: Tucker Hi-Rise
Developer: Great Gulf
Architects: Hariri Pontarini
Pro-Bel services provided: Design, Engineer, Manufacture, Supply and Install, Load Testing, and Inspection


Pro-Bel Technical Solution
At 257 metres tall (843ft), One Bloor required a Building Maintenance Unit (BMU for short and also known as a Roof Car) due to its height. We designed a custom Building Maintenance Unit (BMU / Roof Car)featuring a fixed drum hoist, a 2 stage telescopic boom (arm), and a fixed counterweighted system (trackless). The fixed counterweight allows the stage to move inwards to access the façade under overhangs created by the unique sculptural design. The beautifully design façade is equipped with Intermittent stabilization anchors (ISA’s / Stabilization Buttons) for soft line stabilization. The podium is serviced by roof anchors and davits on level 7 and a davit system on levels 3 to 6 to service the cascading terraces. The davit systems are designed with recessed davit bases to ensure the aesthetic of the building is preserved.
Below is a rendering that provides a general depiction of a Pro-Bel BMU (this is not the One Bloor BMU). It depicts a smaller design on a track around the perimeter of the roof.